Flow Reversal May Improve Embolic Protection


 

SCOTTSDALE, ARIZ. — The flow reversal technique may be a better way to prevent emboli from reaching the brain during a carotid stenting procedure, but not all the evidence is in, Dr. Juan Carlos Parodi said at an international congress on endovascular interventions sponsored by the Arizona Heart Foundation.

In 200 high-risk patients treated so far at his institution, using the Parodi Anti-Emboli system to create flow reversal, 30-day stroke and mortality has been 1.5%, with no ipsilateral ischemic strokes, said Dr. Parodi, professor of surgery and radiology at Washington University, St. Louis.

Those results are good, but not definitive, because clinical outcome is only one way to measure that a technology is truly intercepting emboli created by the procedure, he said. The other ways are diffusion-weighted MRI and transcranial Doppler, both of which have shown that when a distal filter is used during the procedure, it appears that some small emboli do escape and reach the brain, where they do block vessels.

The SAPPHIRE (Stenting and Angioplasty with Protection in Patients at High-Risk for Endarterectomy) trial is the only randomized, controlled trial of a distal filter, Dr. Parodi said. It reported a 30% reduction in 30-day stroke, death, and myocardial infarction with the filter.

But, diffusion-weighted MR studies suggest that even with a filter somewhere between 9% and 43% will still develop new clinical or subclinical lesions, and transcranial Doppler studies suggest that every procedure releases emboli showers, not all of which is caught by a filter. By comparison, new lesions are seen with the MR technique in 6%–12% of patients who have undergone endarterectomy.

How important these small lesions are remains an open question. Most disappear over time. However, studies have reported that necrotic tissue is sometimes seen around the sites of the lesions, and silent infarctions are associated with a doubling of the risk of dementia, Dr. Parodi said.

Dr. Parodi's flow reversal device, the Parodi Anti-Emboli system, uses a balloon inflated in the common carotid proximal to the lesion being treated, obstructing the flow and creating a negative pressure gradient. A second balloon is inflated in the external carotid artery for internal carotid procedures to prevent back-flow, and suction is applied, Dr. Parodi said. The device was recently sold to W. L. Gore and Associates Inc.

Recommended Reading

Strong Role Remains for Primary Lytics Early in MI
MDedge Cardiology
L-Arginine After MI Linked to Higher Mortality
MDedge Cardiology
Telemetry Spots Silent Arrythmia in Stroke Patients
MDedge Cardiology
From Early On, Diabetics Face Higher Stroke Risk
MDedge Cardiology
Cognition Improved by Carotid Artery Stenting : Faster cognition after stenting is related to improved blood perfusion to the brain, imaging study suggests.
MDedge Cardiology
New DES Platforms May Cut Thrombosis Risk
MDedge Cardiology
Nitinol Stents Safe, Effective in Femoral Arteries
MDedge Cardiology
Limited Abciximab in PCI May Facilitate Same-Day Release
MDedge Cardiology
Type A Aortic Dissection Calls for Experience
MDedge Cardiology
20-Year Study Confirms Benefits of MIMA Bypass : The long-term rates of adverse events are decreased, provided the grafts are placed on the two largest vessels.
MDedge Cardiology